![]()
Subchapter F. BLASTING ACTIVITIES
Sec.
211.151. Prevention of damage.
211.152. Control of noxious gasses.
211.153. General requirements for handling explosives.
211.154. Preparing the blast.
211.155. Preblast measures.
211.156. Detonating the blast.
211.157. Postblast measures.
211.158. Mudcapping.
211.159. Electric detonation.
211.160. Nonelectric detonation.
211.161. Detonating cords.
211.162. Safety fuse.
Source This section cited in 25 Pa. Code § 211.173 (relating to monitoring records).
§ 211.152. Control of noxious gases.
A blast shall be conducted so that the gases generated by the blast do not affect the health and safety of individuals. Effects from gases may be prevented by taking measures such as venting the gases to the atmosphere, interrupting the path along which gases may flow, and evacuating people from areas that may contain gases.
§ 211.153. General requirements for handling explosives.
(a) Only a nonferrous, nonsparking tool shall be used to open containers of explosives.
(b) Matches, lighters and smoking are prohibited within 100 feet (30.48 meters) of the blast site and areas where explosives are used or stored.
(c) If it becomes necessary to destroy damaged or deteriorated explosives, the permittee shall immediately contact the manufacturer for technical advice and assistance.
(d) Detonators may not be forced into cartridges of explosive or cast boosters. Detonators shall be completely inserted into a hole in an explosive cartridge made with an approved powder punch or into the detonator well of a cast booster.
(e) Explosives may not be left unattended. They are to be stored in a licensed magazine or kept under the permittees supervision and control.
(f) A loaded blast shall always be under the continuous observation of the blaster-in-charge or a designee.
(g) Shooting or carrying ammunition or firearms on a blast site and in areas where explosives are used or stored is prohibited, except for material needed to initiate the blast.
(h) If blasting activities are conducted in the vicinity of electric lines such as transmission lines or electrified railways, a test shall be made for presence of stray electric currents. Electric blasting caps may not be used if stray electric currents in excess of 50 milliamperes are present.
(i) A package of explosives may not be thrown, slid along floors or over other packages of explosives, or handled roughly.
(j) If an electrical storm approaches an area where there is an activity involving explosives, the area shall be cleared by the permittee or licensee, who shall post guards at all approaches to prevent trespass of unauthorized persons.
(k) Explosives and equipment that are obviously damaged or deteriorated may not be used.
(l) Explosives may not be abandoned.
§ 211.154. Preparing the blast.
(a) The blasting activity permittee shall designate a blaster-in-charge for each blast. The blaster-in-charge shall control and supervise the blasting activity. The blaster-in-charge is responsible for all effects of the blast.
(b) Only equipment necessary for loading blast holes may be allowed to operate within 50 feet (15.24 meters) of the blast site. The Department may establish, in writing, a different distance limitation.
(c) A blaster-in-charge may not prepare or detonate a blast unless another person is present, able and ready to render assistance in the event of accident or injury.
(d) The blaster-in-charge shall make every effort to determine the condition of the material to be blasted from the individual who drilled the blast holes or from the drill log.
(e) Only the blaster-in-charge, other blasters, and up to six assistants per blaster may be at a blast site once loading of blast holes begins.
(f) While loading a blast hole, the following measures shall be followed:
(1) Ferrous material may not be used in the blast hole unless the use is approved by the Department in writing. This includes the use of steel casings, ferrous tools and retrieving equipment.
(2) Only nonferrous, nonsparking tamping sticks may be used in loading a blast hole. Sectional poles connected by brass fittings are permitted, if only the nonferrous, nonsparking end of the pole is used for tamping. Retrieving hooks shall be made from nonsparking metal such as brass or bronze.
(3) When using a pneumatic loading device, every precaution shall be taken to prevent an accumulation of static electricity. A loading operation shall be stopped immediately if static electricity or stray electrical currents are detected. The condition shall be remedied before loading may be resumed.
(4) The blast hole shall be carefully checked for obstructions with a nonferrous, nonsparking tamping pole, a tape, a light or a mirror before it is loaded. The use of magnifying mirrors is prohibited. Explosives may not be forced past an obstruction in a blast hole.
(5) Each blast hole shall be logged throughout the leading process to measure the amount and location of explosives placed in the blast hole. The information is to be recorded on the blast report required by § 211.133 (relating to blast report).
(6) A blast hole containing loose dynamite shall be stemmed but not tamped.
(7) The Department may specify the type and amount of stemming.
(g) Before connecting one loaded blast hole to another, all activity within the blast area shall cease, and all nonessential persons shall retreat to a safe place. The blaster-in-charge shall determine the blast area.
(h) Primers shall be prepared only at the hole to be loaded, immediately prior to loading. The components of the primer are to be kept separated at the collar of the blast hole. The primer may not be slit, dropped, deformed or carelessly handled and may not be tamped or forced into the blast hole.
(i) Immediately upon completing the loading of a blast hole, any wood, paper or other materials used to pack explosives shall be inspected for the presence of explosives and removed to an isolated area. These materials may be burned after the blast has been fired. Persons may not be within 100 feet (30.48 meters) of these burning materials.
(j) Measures shall be taken to reduce the chance of flyrock including:
(1) The use of blasting mats or other protective devices, if, in the opinion of the blaster-in-charge, the measures are necessary to prevent injuries to persons or damage to property.
(2) When blasting to an open, vertical face, checking the face for loose, hanging material or other faults prior to loading the blast holes.
(k) Explosives may not be brought to a blast site in greater quantities than are expected to be needed for that blast. Surplus explosives may not be stored in the blast area.
(l) Before a blast hole is loaded, it shall be checked to ensure that it is cool and does not contain any hot metal or smoldering material remaining from drilling the hole.
(m) The use of abrasive or sharp-edged constituents in stemming material shall be avoided if tamping is necessary and the tamping may sever blasting cap leg wires, shock tubes or detonating cords.
(n) Blasting activities may not be conducted within 800 feet (243.84 meters) of a public roadway unless precautionary measures are taken to safeguard the public. Precautionary measures include stopping or slowing of traffic and posting signs.
§ 211.155. Preblast measures.
Prior to detonating a blast, the blaster-in-charge shall:
(1) Ensure that all excess explosives have been removed from the blast area and are located in a safe area.
(2) Inspect the blast site to ensure that connections are proper and adequate.
(3) Ensure that the blast area is cleared and safeguarded.
(4) In addition to the warning signal, notify all persons who may be in danger.
(5) Ensure that the necessary precautions are in place to protect the public on public roads.
(6) At least 1 minute but no more than 2 minutes prior to detonation, sound a warning signal of three blasts, each lasting approximately 5 seconds. The warning signal shall be of sufficient power to be heard 1,000 feet (304.80 meters) from the blast site.
§ 211.156. Detonating the blast.
(a) A blast may be detonated only between sunrise and sunset unless the Department authorizes a blast at another time of day.
This section cited in 25 Pa. Code § 211.133 (relating to blast reports).
§ 211.158. Mudcapping.
Mudcapping in blasting activities is allowed only if the blaster-in-charge determines that drilling the material to be blasted would endanger the safety of the workers. If mudcapping is necessary, no more than 10 pounds (4.53 kilograms) of explosives shall be used for a blast.
§ 211.159. Electric detonation.
(a) Electric blasting caps shall be tested for continuity with a blasters galvanometer or blasters multimeter specifically designed for testing blasting circuits. Testing shall be done:
(1) Before the primers are made up.
(2) After the blast hole has been loaded but prior to stemming.
(3) As the final connecting of the circuit progresses.
(b) When a shunt is removed from electric blasting cap leg wires, the exposed wires shall be reshunted.
(c) Electric blasting caps may not be employed in a blast if there is any possibility of wires from the circuit being thrown against overhead or nearby electric lines.
(d) An effort may not be made to reclaim or reuse electric blasting caps if the leg wires have been broken off near the top of the cap.
(e) Leg wires on electric blasting caps shall extend above the top of the blast hole. Wire connections and splices are not allowed in the blast hole.
(f) Only solid wire shall be used in a blasting circuit. The use of stranded wire is prohibited.
(g) When electric detonation is used near public roads, signs shall be erected at least 500 feet (152.40 meters) from the blast areas reading: BLAST AREA - SHUT OFF ALL TWO-WAY RADIOS.
(h) A blasting machine is the only permissible source of electrical power for a detonation.
(i) The blasting circuit shall remain shunted until the time for detonation unless the circuit is being tested or connections are being made.
(j) A sticker shall be displayed on blasting machines that shows they have been tested within the last 30 days by procedures recommended by the manufacturer or supplier to ensure performance at rated capacity. If blasting caps are used in the test, they shall be covered with earth or sand.
(k) When electronic detonation is used, the blaster-in-charge shall determine that adequate current, as specified by the manufacturer of the detonators, is available to properly energize the detonators in the circuit.
§ 211.160. Nonelectric detonation.
Nonelectric initiation systems shall be checked and tested for secure connections in accordance with recommendations of the manufacturer of the system in use.
§ 211.161. Detonating cords.
(a) Detonating cord shall be cut from the supply roll immediately after placement in the blast hole. A sufficient length of downlines shall be left at the top of the blast hole for connections to trunk lines. The supply roll shall be immediately removed from the site. Scrap pieces of detonating cord shall be destroyed after connections are made.
(b) A trunk line shall be covered with at least 12 inches (0.30 meter) of earth or sand, unless otherwise authorized by the Department.