Pennsylvania Code & Bulletin
COMMONWEALTH OF PENNSYLVANIA

• No statutes or acts will be found at this website.

The Pennsylvania Code website reflects the Pennsylvania Code changes effective through 54 Pa.B. 488 (January 27, 2024).

25 Pa. Code § 87.107. Hydrologic balance: treatment facilities.

§ 87.107. Hydrologic balance: treatment facilities.

 (a)  At a minimum, facilities and measures for treating discharges from disturbed areas shall be designed, constructed and maintained to treat the runoff from a 10-year, 24-hour precipitation event and any groundwater contribution.

 (b)  Facilities and measures for treating any discharges shall be based on good engineering design and shall include automatic neutralization processes. The Department may approve a manual neutralization system if the Department finds that:

   (1)  Small and infrequent treatment is needed to meet effluent limitations.

   (2)  Timely and consistent treatment is ensured.

 (c)  The design, construction and maintenance of a treatment facility shall not relieve an operator of his responsibility for complying with effluent standards as provided for in §  87.102 (relating to hydrologic balance: effluent standards).

Source

   The provisions of this §  87.107 adopted December 19, 1980, 10 Pa.B. 4789, effective July 31, 1982, 12 Pa.B. 2382; amended July 30, 1982, 12 Pa.B. 2473, effective July 31, 1982, 12 Pa.B. 2382.

Cross References

   This section cited in 25 Pa. Code §  89.173 (relating to performance standards).



No part of the information on this site may be reproduced for profit or sold for profit.


This material has been drawn directly from the official Pennsylvania Code full text database. Due to the limitations of HTML or differences in display capabilities of different browsers, this version may differ slightly from the official printed version.